Your fire system.
Monitored remotely.
Tested automatically.
Triple Star installs and maintains the NOTIFIER INSPIRE™ — the most advanced addressable fire alarm panel available in the UK, built for modern buildings and the full demands of BS 5839‑1:2025.
BS 5839‑1:2025 is now in force (30 April 2025). The new edition introduces cybersecurity requirements for connected panels, updated battery backup calculations, and stricter documentation standards. NOTIFIER INSPIRE is engineered to meet every one of them.
What INSPIRE means for your building.
Here is what changes when Triple Star installs and maintains a NOTIFIER INSPIRE system — across detection, monitoring, compliance, and future-proofing.
Verified between every visit — automatically.
INSPIRE's Self-Test detectors run automated functional tests — generating a controlled amount of smoke into the optical chamber and heating the thermistor — without anyone entering the room. No smoke pole. No engineer on a ladder. One technician can test an entire floor in the time it previously took to test a single corridor, and every result is logged digitally in the CLSS cloud.
Instant notification. Remote diagnosis. Fewer callouts.
INSPIRE connects to Honeywell's Connected Life Safety Services (CLSS) cloud. When a fault or alarm condition occurs, push notifications go instantly to your mobile device and to our engineering team. We can remotely diagnose the issue before anyone travels to site — improving first-time fix rates and dramatically cutting the time your system is out of normal operation.
Built to grow alongside your building.
INSPIRE is built on a modular architecture. It grows detector by detector, panel by panel — without disrupting existing coverage or requiring extensive re-cabling. The E10 starts at 2 loops and expands to 8. Up to 32 panels network together. INSPIRE is also backward compatible with existing CLIP-protocol devices, protecting your current investment.
Compliance documentation ready before we leave site.
After every CLSS-assisted service visit, a compliance certificate is generated directly from the cloud — no manual transcription, no chasing paperwork. Your maintenance report is compliant with BS 5839‑1:2025 and ready the moment our team finishes on-site, exported as PDF and stored in your CLSS account.
INSPIRE changes how a fire system is maintained and monitored — for its entire lifetime.
Self-testing detectors, cloud monitoring via CLSS, and a modular panel combine to reduce business disruption, eliminate unnecessary callouts, deliver instant compliance evidence, and give you a system that genuinely keeps pace with your building. Triple Star manages the entire lifecycle — design, installation, commissioning, and ongoing maintenance — as a single accountable partner.
How INSPIRE works from day one.
Three components — panel, detectors, cloud platform — each purpose-built to complement the others across the full lifecycle of your fire system.
INSPIRE Panel Installed & Commissioned
Triple Star's engineers install and commission your NOTIFIER INSPIRE E10 or E15 panel, wired and configured to EN54-2 and EN54-4. Self-Test detectors are addressed to your building layout and risk category — L1 to L5 or P1/P2 — fully in line with BS 5839‑1:2025.
Securely Connected to CLSS Cloud
A CLSS Gateway connects the panel to Honeywell's cloud platform over your site's IP network, Wi-Fi, or GSM. Communication is encrypted end-to-end. Hosted on Microsoft Azure. GDPR-compliant. Triple Star's team gains live visibility of your system from day one — not just at the next service visit.
Monitor, Maintain & Report — Ongoing
Automated Self-Test keeps detectors verified continuously. Any fault condition triggers instant push notification. When Triple Star attends for the six-monthly inspection required under BS 5839‑1:2025, compliance reports are auto-generated via CLSS and shared with you digitally before our engineers leave site.
NOTIFIER INSPIRE™ E10 — 10” capacitive touchscreenNOTIFIER INSPIRE™
E10 & E15 Series
NOTIFIER's latest generation addressable fire alarm control panel. A modular, networkable system built on the OPAL digital protocol — delivering maximum detection speed with the flexibility to grow alongside your building, while remaining backward compatible with existing infrastructure.
- Capacitive 10” colour touchscreen — intuitive, menu-driven operation with minimal training required
- 2 to 8 addressable loops per panel — 318 devices per loop (159 detectors + 159 modules)
- Network up to 32 panels via ID²NET — peer-to-peer, fault-tolerant ring; fire conditions propagated in under 2 seconds
- Modular slot architecture — 6 slots (to 10) on E10; 12 slots (to 14) on E15
- EN54-2 and EN54-4 certified — third-party approved to UK fire detection standards
- Backward compatible — supports CLIP protocol devices, protecting your existing investment
- Native CLSS Gateway connectivity — cloud integration built in, not bolted on
Honeywell CLSS — accessible on iOS, Android & desktopConnected Life Safety
Services (CLSS)
CLSS is Honeywell's cloud platform for fire system management. It gives facility managers and Triple Star's engineers a real-time, continuous view of your entire system — from any device, from anywhere.
- Real-time fault and alarm notifications pushed directly to your mobile — no polling, no delays
- Remote diagnostics before travelling to site — improving first-time fix rates and reducing unnecessary callout costs
- Multi-site visibility — all buildings under contract from a single dashboard
- Automated compliance reports compliant with BS 5839‑1:2025, generated on completion of every service visit
- Cybersecure by design — end-to-end encrypted, Honeywell Secure Software Development Lifecycle (SSDLC), hosted on Microsoft Azure; meets BS 5839‑1:2025 cybersecurity requirements
- GDPR compliant — all personal data protected under UK regulations
Built for commercial environments of all kinds.
INSPIRE is specified across the full range of building types — wherever compliance, scalability, and minimal disruption to occupants matter most.
Commercial Offices
Hotels & Hospitality
Healthcare & Care Homes
Education & Schools
Retail & Leisure
Full specification.
Everything a specifier, M&E contractor, or building manager needs to assess suitability. All specifications are for the UK market.
Source: NOTIFIER by Honeywell. Specifications subject to change — contact Triple Star for the most current datasheet.

Panel Models & Enclosures
| E10 Part Number | HOP-131-206 |
| E15 Part Number | HOP-134-412 |
| E10 Dimensions (H × W × D) | 445 × 455 × 190mm |
| E15 Dimensions (H × W × D) | 665 × 455 × 250mm |
| Module Slots — E10 | 6 slots, expandable to 10 |
| Module Slots — E15 | 12 slots, expandable to 14 |
| PSU — E10 | 240W |
| PSU — E15 | 480W |
| Mounting Options | Surface, semi-flush, 19” rack |
| Colour | RAL 7022, semi-gloss |
Detection Loop Capacity
| Loops per panel | 2 (expandable to 8 via Dual Loop Modules) |
| Devices per loop | 318 total — 159 OPAL detectors + 159 modules |
| Protocol | NOTIFIER OPAL digital (primary) + CLIP legacy (licensable) |
| Detection zones | 130 on-screen per panel; up to 3,000 across network |
| Max networked panels | 32 via ID²NET |
| Network topology | Peer-to-peer ring — fault-tolerant, no single point of failure |
| Fire condition propagation | Under 2 seconds across full network |
| Max loop cable length | 3,500m on fire-rated cabling |
| EN54 compliance | EN54-2 (CIE) + EN54-4 (Power Supply) + EN54-13 |
Self-Test Detectors
| Available types | Self-Test Optical Heat; Self-Test Optical; Self-Test Heat |
| Smoke test method | Internal smoke generation into optical chamber — real photoelectric response, not software simulation |
| Heat test method | Internal thermistor heating — functional test of thermal sensor element |
| Visual inspection | Bluetooth Low Energy (BLE) beacon — engineer proximity confirmed via CLSS app |
| Flexible testing | Single device / per loop / multiple loops per panel / multiple panels simultaneously |
| EN54 certifications | EN54-5, EN54-7, EN54-17, EN54-29 |
| Address setting | Decimal rotary switches on detector head |
| Sensitivity levels | 6 configurable levels, including thermal-only mode |
Electrical & Environmental
| Supply voltage | 230V AC, 50Hz (−15% / +10%) |
| Mains input current | 1.2A (E10 240W PSU) / 2.3A (E15 480W PSU) |
| Battery backup — E10 | Max 24Ah (2 × 12V sealed lead-acid, YUASA NP series) |
| Battery backup — E15 | Max 38Ah (2 × 12V sealed lead-acid) |
| Operating temperature | −5°C to +40°C |
| Relative humidity | 5% to 95%, non-condensing |
| Ingress protection | IP30 (EN60529) |
| EMC emissions | EN61000-6-3 |
| Safety standard | EN62368-1 |
CLSS Connectivity & Cybersecurity
- Connection via fixed CLSS Gateway — IP network, Wi-Fi, or internal GSM (no external hotspot required)
- Gateway powered at 24V DC from panel CIE or separate PSU
- All communications encrypted — Honeywell Secure Software Development Lifecycle (SSDLC)
- Hosted on Microsoft Azure — enterprise-grade availability and security
- On-site Bluetooth pairing required to authenticate remote engineer access
- Remote access window configurable between 10 minutes and 10 hours post pairing
- Meets BS 5839‑1:2025 cybersecurity requirements for remotely connected panels
- GDPR compliant — personal data protected under UK data regulations
- Compatible with iOS and Android (CLSS app) and all modern desktop browsers
Standards & Certifications
- BS 5839-1:2025 — design, installation, commissioning and maintenance of fire detection and alarm systems in non-domestic premises
- EN54-2:1997 +A1:2006 — Control and Indicating Equipment
- EN54-4:1997 +A1:2002 +A2:2006 — Power Supply Equipment
- EN54-13 — Compatibility and connectability of components
- EN54-5, EN54-7, EN54-17, EN54-29 — Self-Test detector certifications
- Regulatory Reform (Fire Safety) Order 2005 — system design compliant
- Approved Document B — referenced standard for building regulations in England
- BS 7671 — IET Wiring Regulations; all cabling installed to current edition
The system is only as good as the company behind it.
NOTIFIER INSPIRE is an exceptional product. But a fire system requires careful design, precise commissioning, and a long-term maintenance relationship to perform as intended across its entire lifetime. That is where Triple Star comes in.
Established in 2006, our Managing Director sits as a BSI committee member and has lobbied directly for the standards that govern the systems we install. We don't cut corners — because the people at risk if we did are your staff and your building's occupants.
Authorised NOTIFIER installer and CLSS service representative. Under BS 5839‑1:2025 and NOTIFIER's own requirements, only trained and certified partners may commission CLSS-connected systems, conduct Self-Test service visits, and generate CLSS compliance reports.
Full lifecycle accountability. We design, install, commission, and maintain your system as a single partner. No handoffs between contractors, no gaps in responsibility, no ambiguity when something needs attention.
BS 5839‑1:2025 compliant maintenance programme. Six-monthly service visits structured to the new standard, with automated CLSS compliance reports delivered digitally on completion.
Flexible leasing available. We can structure your INSPIRE installation as a leased arrangement, spreading the investment with no large upfront outlay and keeping cash flow predictable.

Authorised Engineered Systems Distributor
Triple Star is trained and certified by NOTIFIER to install, commission, and maintain INSPIRE systems and operate the CLSS monitoring platform on behalf of our clients.
NOTIFIER INSPIRE™ Product Brochure & System Overview
Full system overview, Self-Test technology, CLSS platform guide and panel specifications — free PDF, no sign-up required